Search results for 'Drive' and 'x'='x and 1>1'
-
-
An error occurred, please try again later.
Loading, please wait...
-
- Connection 1/4", 3/8", 1/2", 3/4", 1"
- G thread or NPT thread
- Pressure range 0.5 ... 40 bar
- Electrical operation
- Voltage 24 V DC, 110 V AC, 230 V AC
- 2/2-way shut-off valve (NC)
- Sealing material NBR, fluoro elastomer
- For the actuation of gaseous and fluid media in open
Learn More
-
- Widths: 10, 14 and 18 mm
- Flow rates: 400, 800 and 1600 l/min
- Diverse valve functions and
- additional functions
- Connection to the CPX electronic terminal via CP interface.
Learn More
-
- Flow rate 360 to 700 l/min
- Width 10, 20 mm
- Flexibility: flexible pressure supply, variable pressure zones, additional power supply at any position
- Serial valve pilot - up to 64 valve positions or 128 solenoid coils
- Open for PROFIBUS DP, Interbus, CANopen, DeviceNet, CC Link
- Pressure range -0.9 to 10 bar
- Protection class IP65
- Electrical I/O, CPI, AS interfaces and fieldbus connections by modular type CPX electrical terminal.
Learn More
-
- Sub-base in polymer technology
- Tamper-proof fixed throttle
- 3 valve sizes in the mix, expandable in individual steps
- Flow rate 160 ... 870 l/min.
- Width 10, 14 and 20 mm
- Push-in connector 3, 4, 6, 8, ,10, 12 mm
- CTEU connection
- Protection class IP65, IP67
- Valve functions 5/2, 5/3, 2x3/2, 2x2/2 and special
Learn More
-
-
- Caps for non-detenting and sealed manual overrides.
Learn More
-
- Cover caps for closing
- unused connections.
Learn More
-
- Operating components for ISO valve terminals.
Learn More
-
- Mounting screws and nuts for valve terminal
Learn More
-
- Comprehensive function integration with technology modules
- Installation variants
- Stand-alone as remote I/O
- With valve terminal VTSA-F
- With valve terminal VTSA
- With valve terminal MPA-L
- With valve terminal MPA-S
- I/O modules
- Optional CODESYS controller
Learn More
-
- Fieldbus module for valve modules VTOC, VTUB, VTUG, MPAC, MPAL and CPV
- Bus protocols:
- CANopen
- Profibus DP
- DeviceNet
- AS-Interface
- CC-Link
- EtherCAT
- EtherNet/IP
- Modbus/TCP
- PROFINET
- CPI-B
- Optional: two I-Port interfaces via electrical connection block CAPC base for installation system CTEL
Learn More
-
- Complete concept for decentralised machine and system structure
- 4 installation strings per CP interface
- 10 metre line length per string (radius)
- 4 CP modules per string
- 32 inputs and 32 outputs per string.string.
Learn More
-
- Addressable volume range from microlitres to millilitres
- High level of precision with a wide volume range
- Single-channel dispense head or multi-channel mounted on a rail
- 8-channel dispense head for microwell plates
- Media-isolated solenoid valve VODA-FD72
- Pressure 0 – 0.5 bar
- Coil 24 VDC
- Material PPS, seal FPM
Learn More
-
- NSF-H1 grease filling, FDA approved materials
- Degree of protection IP69K, redundant sealing system
- Clean design: easy to clean
- Valves 2x 2/2, 2 x 3/2-way, 5/2-way monostable, 5/2-way double solenoid, 5/3-way
- Standard nominal flow rate 450 ... 760 l/min
- Valve width 14 mm
- 2 ... 32 valve positions, 2 ... 32 solenoid coils
- Modular, with valve positions in single grid
- Multi-pin plug connection, fieldbus connection I-Port / IO-Link
- Protection class IP65, IP67, IP69K
Learn More
-
- Directly actuated miniature valves
- Width: 10 mm
- Standard nominal flow rate: 10 ... 14 l/min
- Voltage: 5, 12, 24 V DC
- Switching time: 4 ms
- Pressure: -0.9 ... 8 bar
- Protection: IP40
- Individual or multi-pin plug connection
Learn More